Compex-systems Advanced SerialRAID Adapters SA33-3285-02 Manual de usuario Pagina 480

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 531
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 479
12. (from step 11)
Did the Certify service aid fail again?
NO
a. Ask the user to recreate the array.
b. Go to step 22 on page 467.
YES
a. Exchange the failing disk drive for a new one (see Exchanging Disk
Driveson page 319).
b. Go to step 37 on page 473 to add the disk drive to the group of disk
drives that are available for use by the RAID manager.
13. (from step 4)
An array is in the Degraded state if one member disk drive of the array is missing,
or has failed, and a write command has been sent to that array. When an array is
in the Degraded state, its data is not protected.
a. Type smitty ssaraid and press Enter.
b. Select Change/Show Use of an SSA Physical Disk.
c. Go to step 14 on page 461.
460 Users Guide and Maintenance Information
Vista de pagina 479
1 2 ... 475 476 477 478 479 480 481 482 483 484 485 ... 530 531

Comentarios a estos manuales

Sin comentarios