Compex-systems Advanced SerialRAID Adapters SA33-3285-02 Manual de usuario Pagina 172

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 531
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 171
All the free disk drives that are listed are large enough and have the correct format
to become part of the RAID-Copy array for hdisk5.
2. With a disk drive from the list (for example, 000629CD8A3900D), create your
RAID-Copy array. Type:
ssaraid -C -l ssa2 -t raid_copy -s 000629CD8A3900D -r hdisk5
A message is displayed; for example:
185439188B4F4CT created
000629CD8A3900D changed
Your RAID-copy array is 185439188B4F4CT.
3. Couple the RAID-Copy array to the parent RAID array. Type:
ssaraid -A -l ssa2 -i couple -n hdisk5 -a raid_copy=185439188B4F4CT
-a copy_verify_writes=true
A message is displayed; for example:
185439188B4F4CT changed
185439188B4F4CT coupled
The copy operation starts immediately the array is coupled. If the RAID-Copy array
already contains a copy of data from another array, you must use the force flag to
reuse the array. Add:
-a force=yes
to the end of the command that is shown at the start of this step.