Compex-systems Advanced SerialRAID Adapters SA33-3285-02 Manual de usuario Pagina 345

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 531
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 344
23. If the disk drive that you are installing is a replacement for a disk drive that was a
member of an SSA RAID array, go to step 24. Otherwise, go no further with these
instructions.
24. Type smitty ssaraid and press Enter.
25. Select Change/Show Use of an SSA Physical Disk.
The pdisk that has been exchanged is listed under SSA Physical Disks that are
system disks.
26. Select the pdisk from the list.
27. Change the Current Use parameter to Hot Spare Disk or to Array Candidate
Disk.
Note: It is the user who should make the choice of Current Use parameter. That
choice should be:
v Hot Spare Disk if the use of hot spares is enabled for the RAID arrays
on the subsystem
v Array Candidate Disk if the use of hot spares is disabled for the RAID
arrays on the subsystem.
Chapter 15. Removal and Replacement Procedures 325
Vista de pagina 344
1 2 ... 340 341 342 343 344 345 346 347 348 349 350 ... 530 531

Comentarios a estos manuales

Sin comentarios